search
Menu
 

MIZ-21C

SPECIFICATIONS

Specifications listed here are subject to change.

Size (H × W × D) 267 × 122 × 38 mm (10.5 × 4.8 × 1.5 in)
Weight (including batteries and cover) 1.22 kg (2.7 lb)
Multi-Touch Display 5.7 in (480 x 640 pixels)
Battery Life 8 hr. per charge
Eddy Current Connector 18-Pin Lemo
Eddy Current Array Connector 26-Pin Lemo
Connectivity USB 2.0, Wi-Fi, Bluetooth
Encoders 2 axes, quadrature
Probe Recognition and Setup Automatic, Zetec Coil ID Chip
Coil Inputs MIZ-21C-SF: 1, MIZ-21C: 1, MIZ-21C-ARRAY: 3
Frequencies Per Timeslot MIZ-21C-SF: 1, MIZ-21C: 2, MIZ-21C-ARRAY: 2
Data Channels MIZ-21C-SF: 32, MIZ-21C: 64, MIZ-21C-ARRAY: 192
Maximum Probe Coils MIZ-21C-SF: 2, MIZ-21C: 2, MIZ-21C-ARRAY: 32
Frequency Range 5 Hz to 10 MHz
Generator Output Up to 19 Vpp
Injection Modes Continuous and Super-Multiplex
Receiver Gain 10 – 53 dB, 43 dB range
Data Resolution 16 bits
Acquisition / Sampling Rate Up to 25,000 per second
Probe Drive 50 Ohm
Filters Adjustable CC, Median, High Pass, Low Pass, Bandpass, Spike
Alarms Adjustable Box, Audio adjustable volume, Headphone support
Conductivity Frequency 60, 120, 240 and 480 kHz
Conductivity Specification Digital readout in 0.9 to 110 %IACS (0.5 to 70 MS/m), Accuracy within ±0.5% IACS from 0.9% to 65% IACS and within ±1.0% of values over 65%
Non-Conductive Coating Thickness Can measure non-conductive coating thickness from 0 mm to 1.000 mm. Accuracy of 0.025 mm (±0.001 in.) over a 0 mm to 0.64 mm range
Rotating Scanner MIZ-21C-SF: No, MIZ-21C: Yes, MIZ-21C-ARRAY: Yes Zetec Rotating Scanner, Others
Maximum Data File Size 60 MB
Languages English, Spanish, French, German, Chinese
Storage 8 GB SSD Internal, Any size through USB expansion
Instrument Calibration Compliant with ISO/IEC 17025:2005, Meets or exceeds manufacturer's requirments
Voltage 100 to 240 VAC, Auto-Switching
Frequency 50 to 60 Hz
Output Voltage 15 VDC
Maximum Power 40 W
Operating Temperature Range -10°C to 45°C (14°F to 113°F)
Storage Temperature Range -20°C to 70°C (-4°F to 158°F) (w/out batteries)
Relative Humidity 95% non-condensing